Compare CP's to CP's...
How do your nozzles stack up?


For Drift Control - 35 Liters Per Hectare

  CP-11TT Flat Fans CP-03 - Standard Nozzles CP-07 & 09 - Straight Streams

130 Knots

38 Nozzles

#20 40° Tip, 42 psi 8° Default Angle VMD - 292 RS - 0.83 9.10% Under 200 Microns 0.43% Under 100 Microns .125/.078 Orifices, 43 psi 30° Deflector VMD - 226 RS - 2.17 38.84% Under 200 Microns 15.26% Under 100 Microns .125/.078 Orifices, 43 psi 0° Straight Stream Setting VMD - 320 RS - 1.27 20.43% Under 200 Microns 7.19% Under 100 Microns

122 Knots

36 Nozzles

#20 40° Tip, 41 psi 8° Default Angle VMD - 323 RS - 0.90 6.14% Under 200 Microns 0.01% Under 100 Microns .125/.078 Orifice, 41 psi 30° Deflector VMD - 253 RS - 2.02 28.35% Under 200 Microns 10.66% Under 100 Microns .125/.078 Orifice, 41 psi 0° Deflector VMD - 350 RS - 127 14.43% Under 200 Microns 4.82% Under 100 Microns

112 Knots

36 Nozzles

#20 40° Tip, 38 psi 8° Default Angle VMD - 362 RS - 0.97 3.84% Under 200 Microns 0.01% Under 100 Microns .125/.078 Orifice, 38 psi 30° Deflector VMD - 275 RS - 2.16 19.16% Under 200 Microns 6.50% Under 100 Microns .125/.078 Orifice, 38 psi 5° Deflector VMD - 348 RS - 1.37 12.21% Under 200 Microns 3.73% Under 100 Microns

105 Knots

36 Nozzles

#25 40° Tip, 34 psi 8° Default  Angle VMD - 390 RS - 1.02 2.83% Under 200 Microns 0.01% Under 100 Microns .125/.078 Orifice, 34 psi 30° Deflector VMD - 306 RS - 1.85 15.13% Under 200 Microns 5.68% Under 100 Microns .125/.78 Orifice, 34 psi 5° Deflector VMD - 378 RS - 1.32 10.26% Under 200 Microns 3.11% Under 100 Microns

For Smaller Droplets - 270 to 300 Micron VMD - 35 L/ha

  CP-11TT Flat Fans CP-03 - Standard Nozzles CP-07 & 09 - Straight Streams

130 Knots

38 Nozzles

#20 40° Tip, 42 psi 15° Down Angle w/Swivel VMD - 280 RS - 0.78 11.55% Under 200 Microns 1.06% Under 100 Microns .125/.078 Orifices, 43 psi 30° Deflector VMD - 226 RS - 2.17 38.84% Under 200 Microns 15.26% Under 100 Microns .125/.078 Orifices, 43 psi 5° Deflector VMD - 274 RS - 1.41 23.57% Under 200 Microns 8.17% Under 100 Microns

122 Knots

36 Nozzles

#20 40° Tip, 41 psi 30° Down Angle w/Swivel VMD - 288 RS - 0.78 11.55% Under 200 Microns 1.21% Under 100 Microns .125/.078 Orifice, 41 psi 30° Deflector VMD - 253 RS - 2.02 28.35% Under 200 Microns 10.66% Under 100 Microns .125/.078 Orifice, 41 psi 30° Deflector VMD - 301 RS - 1.16 18.04% Under 200 Microns 5.88% Under 100 Microns

112 Knots

36 Nozzles

#20 40° Tip, 38 psi 45° Down Angle w/Swivel VMD - 291 RS - 0.79 12.41% Under 200 Microns 1.55% Under 100 Microns .125/.078 Orifice, 38 psi 30° Deflector VMD - 275 RS - 2.16 19.16% Under 200 Microns 6.50% Under 100 Microns .125/.078 Orifice, 41 psi 30° Deflector VMD - 348 RS - 1.11 11.98% Under 200 Microns 3.54% Under 100 Microns

105 Knots

36 Nozzles

#25 40° Tip, 38 psi 60° Down Angle w/ Swivel VMD - 281 RS - 0.78 15.11% Under 200 Microns 2.21% Under 100 Microns .125/.078 Orifice, 34 psi 55° Deflector VMD - 301 RS - 0.87 13.04% Under 200 Microns 3.96% Under 100 Microns .125/.078 Orifice, 34 psi 30° Deflector VMD - 370 RS - 0.99 10.64% Under 200 Microns 3.31% Under 100 Microns


RS=Relative Span=Measurement of the evenness of the droplet spectrum in the middle 80% of the spray volume. The smaller the number, the more even the spray.
Outside of recommended range.

PDF Version of this chart.